Consumer properties
The settings in the Consumer window before placing the element on the drawing will be set as in the General Settings. They can be modified at this point or later by using the properties button to change data in already inserted elements.
General data
- Scheduling
- Consumer name – by default, ‘’Consumer’’,
- Delivery group– set as in the general settings window, determination of the delivery order.
-
Building connection
-
Wall Seals – specifies protection and seal material for pipes entering buildings (going through the wall):
- None – wall seals will not be selected into bill of material.
-
NPW sleeve– wall seals for non-pressurized water areas. The set contains a wall sleeve and a shrink sleeve. The set contains a wall sleeve and a shrink sleeve.
-
NPW through sealing– wall seals for non-pressurized water areas. The set contains the wall through sealing and the clamping ring.
- PWP – wall seals for pressurized water areas <0.3 bar.
- PWS – wall seals for pressurized water areas >0.3 bar or with wall over 200mm thickness.Consist of PWP wall seal and additional Uponor Ecoflex insert which should be to dissipate any stresses.
-
Heating system
-
Input
- Power [kW] – calculations will be based on power value given in kW units. Previously entered power values can be modified by this window separately for each Consumer.
- Flow [l/s] – calculations will be based on flow value given in l/s units, further set in Consumers.
-
Consumer pressure drop [kPa] – pressure drop including required minimum pressure on the plumbing fixtures in the building and pressure losses on the installation. This value will be added to pump pressure head.
-
Pipes
- Additional pipe - possibility to add extra amount of pipe to the bill of material. The program selects the bigger value from provided for HS or DWS system. For example, if in DWS system add 2m and in the HS system add 4m, the program assumes 4m to the calculations and will increase by this value the bill of materials.
-
Fittings
- Use Q&E fittings – Q&E fittings will be used to create junction connections and connection points.
- Use Wipex fittings – Wipex fittings will be used to create junction connections and connection points.
If both are checked the plugin will first look for possible junction solutions using Tees, then, H-Vaults and the Chambers. - Connection type – depending on the selected fitting type choose the item from the drop-down list:
Fitting Type Q&E
Product / Code | Reference number | |
---|---|---|
Adapter male thread PL | QE-MTPLR | 1023003 1023005 1023006 1023007 1023008 1047191 |
Adapter male thread PL G | QE-MTPLG | 1058426 1033435 1091850 1046424 1033436 1033437 1091851 1033438 1091852 1047862 1091853 1047863 1047864 1091851 1091852 1091853 |
Adapter male thread PL W | QE-MTPLG | 1008730 1008732 1008866 1008730 1022290 1008867 |
Adapter female thread PL | QE-FTPL | 1023012 1023013 1047866 1047867 1023026 1058464 1023009 1091848 1023010 1091849 1023011 |
Elbow adapter male thread PL | QE-MTPLE | 1058471 1058472 1023019 1023020 1023021 1023022 1047877 |
Elbow adapter female thread PL | QE-FTPLE | 1023023 1091859 1023024 1091860 1023025 1023026 |
Coupling PL | 1058467 1047193 1047194 1047195 1047193 1047194 1047195 | |
Adapter male thread DR | QE-MTDR | 1063735 1063736 1063806 1118974 1063732 1063733 1063734 1063737 |
Adapter male thread DR W | QE-MTDRW | 1063810 1063724 1063725 1063727 1063728 1063810 |
Elbow adapter male thread DR | QE-MTDRE | 1063748 1063750 |
Adapter PL QE | RS-QE | 1047021 1047022 1047023 1047024 1047026 |
Elbow PPSU | 1008679 1008680 1008681 1001245 1008683 1042859 1042858 1091863 1085080 | |
Coupling PPSU | 1008671 1001235 1008673 1042866 1042865 |
Fitting Type Wipex
Product | Reference number | |
---|---|---|
Elbow (elbow + coupling) | e.g., 1018350 1018328 | |
Coupling | e.g., 1018336 | |
Fix Point (end cap, coupling, fixpoint sleeve) | e.g., 1018336 1018306 1018302 1018355 | |
Socket (end cap, coupling, sleeve) | e.g., 1018336 1018306 1018355 | |
Fix point no sleeve | e.g., 1018336 1018306 1018302 | |
Flange (only single pipe) | 1018359 1018360 1018361 1018362 1018363 1018364 1018365 | |
Jointing Equal | 1042972 1042973 1042980 1042984 1042981 1042985 1042986 1042987 1078365 1121635 1121636 1042970 1042974 1042979 1042983 1042982 |
- Dimension – software calculates the appropriate fitting dimension based on the pipe diameter. Selection of different fitting diameter is possible if another fitting is available in the country portfolio.
-
Additional elements to connection type – additionally to the selected connection type, the program gives the possibility to add elements as follow:
- Entry bend – house connection, L-curve pipe, except quattro pipe,
- Transit through coupling – except quattro pipe,
- Transit through elbow – except quattro pipealt text
-
Add bending fixtures – add elements to bend the pipe with pipe bend support, e.g. 1034302,1034303.
Domestic water system
- Input
- Number of apartments – method of the calculations. If this calculation method was selected in general settings, this field will be modifiable.
- Flow [l/s] – calculations will be based on flow value given in l/s units. If this calculation method was selected in general settings, this field will be modifiable.
- Consumer pressure drop [kPa] – pressure drop including required minimum pressure on the plumbing fixtures in the building and pressure losses on the installation. This value will be added to pump pressure head.
- Pipes
- Additional pipe - possibility to add extra amount of pipe to the bill of material. For Quattro pipes, program selects the bigger value from provided for HS or DWS system. For example, if in DWS system add 2m and in the HS system add 4m, the program assumes 4m to the calculations and will increase length of quattro pipe by this value in the bill of materials.
-
Fittings
- Use Q&E fittings – Q&E fittings will be used to create junction connections and connection points.
- Use Wipex fittings – Wipex fittings will be used to create junction connections and connection points. If both are checked the plugin will first look for possible junction solutions using Tees, then, H-Vaults and the Chambers.
- Connection type – depending on the selected fitting type choose the item from the drop-down list: Fitting Type Q&E
Product / Code | Reference number | |
---|---|---|
Adapter male thread PL | QE-MTPLR | 1023003 1023005 1023006 1023007 1023008 1047191 |
Adapter male thread PL G | QE-MTPLG | 1058426 1033435 1091850 1046424 1033436 1033437 1091851 1033438 1091852 1047862 1091853 1047863 1047864 1091851 1091852 1091853 |
Adapter male thread PL W | QE-MTPLG | 1008730 1008732 1008866 1008730 1022290 1008867 |
Adapter female thread PL | QE-FTPL | 1023012 1023013 1047866 1047867 1023026 1058464 1023009 1091848 1023010 1091849 1023011 |
Elbow adapter male thread PL | QE-MTPLE | 1058471 1058472 1023019 1023020 1023021 1023022 1047877 |
Elbow adapter female thread PL | QE-FTPLE | 1023023 1091859 1023024 1091860 1023025 1023026 |
Coupling PL | 1058467 1047193 1047194 1047195 1047193 1047194 1047195 | |
Adapter male thread DR | QE-MTDR | 1063735 1063736 1063806 1118974 1063732 1063733 1063734 1063737 |
Adapter male thread DR W | QE-MTDRW | 1063810 1063724 1063725 1063727 1063728 1063810 |
Elbow adapter male thread DR | QE-MTDRE | 1063748 1063750 |
Adapter PL QE | RS-QE | 1047021 1047022 1047023 1047024 1047026 |
Elbow PPSU | 1008679 1008680 1008681 1001245 1008683 1042859 1042858 1091863 1085080 | |
Coupling PPSU | 1008671 1001235 1008673 1042866 1042865 |
Fitting Type Wipex
Product | Reference number | |
---|---|---|
Elbow (elbow + coupling) | e.g., 1018350 1018328 | |
Coupling | e.g., 1018336 | |
Fix Point (end cap, coupling, fixpoint sleeve) | e.g., 1018336 1018306 1018302 1018355 | |
Socket (end cap, coupling, sleeve) | e.g., 1018336 1018306 1018355 | |
Fix point no sleeve | e.g., 1018336 1018306 1018302 | |
Flange (only single pipe) | 1018359 1018360 1018361 1018362 1018363 1018364 1018365 | |
Jointing Equal | 1042972 1042973 1042980 1042984 1042981 1042985 1042986 1042987 1078365 1121635 1121636 1042970 1042974 1042979 1042983 1042982 |
-
Additional elements to connection type – additionally to the selected connection type, the program gives the possibility to add elements as follow:
- Entry bend – house connection, L-curve pipe, except quattro pipe,
- Entry bend – house connection, L-curve pipe, except quattro pipe,
- Transit through coupling – except quattro pipe,
- Transit through elbow – except quattro pipealt text
- Entry bend – house connection, L-curve pipe, except quattro pipe,
-
Add bending fixtures – add elements to bend the pipe with pipe bend support, e.g. 1034302,1034303.
Annotation
- Settings
If the window has been opened by properties, the changes made here should be overwritten in the inserted elements on the drawing. -
Annotation type:
- Abbreviations – e.g., QHS [kW] = 45,
- Full Name – e.g., Power [kW] = 45.
- Font Size – indicates fonts size in AutoCAD units,
- Item name.
- Abbreviations – e.g., QHS [kW] = 45,
-
HS system
Information with checked boxes will be displayed on added manually or automatically annotations for objects in the drawing. - DWS system
Information with checked boxes will be displayed on added manually or automatically annotations for objects in the drawing.